Everything Smart

Homey Sensors and Controls for Pro

Understand the sensors and controls available for Everything Presence Pro in Homey and how to use them in your setup.

Everything Presence Pro combines PIR motion, static presence and target tracking. Homey exposes individual readings as well as a configurable main motion alarm.

Choose the main motion source

Open the Pro device in Homey and go to Settings > Motion Source. This controls the main motion alarm used by standard motion Flows.

Source Use
Occupancy (Combined) Start here for general room-presence automations.
PIR Only Use fast movement detection without waiting for mmWave presence.
mmWave (Combined) Use the combined mmWave presence signal.
Static Presence (SEN0609) Use the static presence sensor on its own.
Tracking (LD2450) Use the tracking sensor's presence signal.

Changing Motion Source also changes the meaning of existing Flows using the main motion alarm. Individual sensor capabilities remain separate.

Sensors and controls

Homey reading or control Capability Purpose
Main motion alarm alarm_motion Presence or motion from the selected Motion Source.
PIR alarm_generic.pir PIR motion state.
Combined mmWave alarm_generic.mmwave Combined mmWave presence state.
Static presence alarm_generic.static_presence SEN0609 presence state.
Tracking presence alarm_generic.tracking LD2450 presence state.
Illuminance measure_luminance Room light level in lux.
Temperature / humidity measure_temperature, measure_humidity Environmental readings; internal heat can affect accuracy.
Zones 1-4 alarm_generic.zone1_occupancy through alarm_generic.zone4_occupancy Occupancy in each configured tracking zone.
Targets 1-3 measure_x, measure_y, measure_distance, measure_angle, measure_speed, each suffixed with .target1, .target2 or .target3 Advanced tracking readings for each target slot. Slots are not persistent identities for individual people.
RGB LED onoff.led_rgb, dim, light_hue, light_saturation LED power, brightness, colour and saturation.
Relay onoff.relay Relay output control.

Configure zones and exclusion areas

  1. Open the Pro's device settings in Homey.
  2. Under Zone 1, set Begin X, End X, Begin Y and End Y in millimetres to define your area.
  3. Set the zone's Off Delay (s), save, and walk into and out of the area while watching its occupancy state.
  4. Repeat for Zones 2-4 as needed. Start with one small, tested area before adding more.
  5. Use Exclusion Zones to configure Mask 1 and Mask 2 when tracking areas should be ignored. Test the resulting behaviour after changing a mask.

Zone occupancy is a tracking signal. Do not assume a zone will remain occupied solely because the separate static sensor detects someone elsewhere in the room.

Tune detection

Settings group Controls
Timeouts Combined Occupancy Off Delay and PIR Off Delay, in seconds.
Static Presence (SEN0609) Minimum, maximum and trigger distance in metres; on/off delays; trigger and sustain sensitivity.
Tracking (LD2450) Maximum distance in centimetres, off delay in seconds and installation angle.
Environmental Calibration Temperature, humidity and illuminance offsets.
Advanced Stale Target Timeout, Auto-Clear Stuck Targets, Upside Down Mounting, LD2450 Bluetooth and Static Presence Sensor Enabled.

Change one setting at a time and retest with an occupied and empty room. Pay attention to units: static distances use metres, tracking range uses centimetres, and zone coordinates use millimetres.

LED and relay behaviour

LED Mode offers Manual Control, Environmental, Presence, and Environmental + Presence. Choose Manual Control when you want to set LED colour directly. Environmental behaviour depends on the device's firmware and installed sensors.

Relay Trigger Mode offers Disabled, Motion Only, Presence Only, and Motion or Presence. Review the selected mode before using relay actions in Flows, because automatic device behaviour can also drive the output. See Alarm Panel Integration for hardware and wiring details.

Next steps