The Everything Presence Pro has two mmWave sensors with different characteristics. This guide helps you optimize both for your room.
Understanding the Two Sensors
Sensor | Range | Best For | Key Settings |
|---|---|---|---|
Static (SEN0609) | Up to 25m | Detecting still people | Range, Sensitivity |
Tracking (LD2450) | Up to 6m | Location, zones, movement | Range, Zones |
Both sensors contribute to the main Occupancy entity, so tuning either can improve your results.
Quick Tuning Checklist
Set Static Presence Max Range to match your room depth
Set Tracking Detection Range to match your room depth
Add exclusion zones for problem areas (windows, fans)
Adjust timeouts for your use case
Fine-tune sensitivity if needed
Tuning the Static Presence Sensor (SEN0609)
Range Settings
Setting | What It Does | Recommendation |
|---|---|---|
Min Range | Ignores detections closer than this | Usually 0m (no minimum) |
Max Range | Ignores detections beyond this | Set to room depth or slightly less |
Trigger Range | Initial detection threshold | Usually same as Max Range |
To apply range changes:
Set your desired values
Click Apply Static Range Settings button
Sensitivity Settings
Setting | What It Does | Higher Value |
|---|---|---|
Trigger Sensitivity | How easily detection starts | More sensitive, more false triggers |
Sustain Sensitivity | How easily detection maintains | More sensitive, stays on longer |
Recommended starting values:
Trigger Sensitivity: 5 (default)
Sustain Sensitivity: 7 (default)
To apply sensitivity changes:
Set your desired values
Click Apply Static Sensitivity Settings button
Common Issues & Fixes
Issue | Solution |
|---|---|
Detects through walls | Reduce Max Range to stop before the wall |
Misses still people | Increase Sustain Sensitivity (7-9) |
False triggers when empty | Reduce sensitivities, check for moving objects |
Slow to detect | Increase Trigger Sensitivity, reduce On Delay |
Tuning the Tracking Sensor (LD2450)
Detection Range
Set Tracking Detection Range to approximately your room depth in cm:
Small room (3m): 300cm
Medium room (4-5m): 400-500cm
Maximum (6m): 600cm
Zone Configuration
For precise control, use the Zone Configurator to:
Create detection zones for specific areas
Add exclusion zones to ignore problem spots
Visualize real-time tracking
Exclusion Zones
Use exclusion zones for:
Windows (people walking by outside)
Ceiling fans
Curtains that move
Areas detected through thin walls
Update Rate Settings
Setting | Trade-off |
|---|---|
Tracking Update Rate | Faster = more responsive, more CPU usage |
Target Update Rate | Faster = more HA database writes |
Target Tracking Detail | More detail = more entities updated |
For most users: Keep defaults. Only reduce if you have performance issues.
Timeout Settings
Room Type | Occupancy Timeout | Motion Timeout |
|---|---|---|
Hallway/passage | 15-30s | 10s |
Bathroom | 60-120s | 15s |
Kitchen | 30-60s | 10s |
Living room | 120-300s | 15s |
Office/desk | 300-600s | 15s |
Bedroom | 300-600s | 15s |
Longer timeouts prevent lights turning off while you're still present but sitting still.
Combining Both Sensors
The Pro's Occupancy entity combines both mmWave sensors plus PIR:
Occupancy = PIR Motion OR Static Presence OR Tracking PresenceThis means:
PIR provides instant motion response
Static sensor provides long-range stationary detection
Tracking sensor provides zone awareness
You can also use individual sensors for specific automations:
Use Motion (PIR) for instant-on lighting
Use Static Presence for long-range detection
Use Tracking Presence or Zone entities for location-specific triggers
Troubleshooting Detection Issues
Sensor detects when room is empty
Check for moving objects (fans, pets, curtains)
Reduce Max Range if detecting through walls
Add exclusion zones for problem areas
Lower sensitivity settings
Sensor misses people who are sitting still
Increase Static Sustain Sensitivity (7-9)
Ensure line of sight to the seating area
Check Max Range includes the seating area
Detection is slow
Increase Static Trigger Sensitivity
Reduce Static On Delay to 0
Ensure adequate Tracking Update Rate
Zones not working correctly
Use Zone Configurator to visualize real-time tracking
Verify zone coordinates cover the intended area
Check exclusion zones aren't masking valid detections