Everything Smart

Technical Entity Reference

Look up Everything Presence sensor entities and controls to understand their purpose when configuring your smart home.

Complete reference of all Home Assistant entities for EP1 and EPL, including default values and valid ranges.


Everything Presence One (EP1) - SEN0609

Binary Sensors

Entity Description Default
mmWave Presence detected by mmWave sensor -
PIR Motion detected by PIR sensor -
Occupancy Combined PIR + mmWave (either triggers on) -

Sensors

Entity Unit Description
Temperature °C Room temperature
Humidity % Relative humidity
Illuminance lx Ambient light level
mmWave Target Distance* m Distance to detected target
mmWave Target Speed* m/s Speed of detected target
mmWave Target Energy* - Signal strength of detection
mmWave Target Count* - Number of targets detected

*Disabled by default. Enable in entity settings.

Configuration Numbers

Entity Range Default Step Description
mmWave Minimum Distance 0.6-25 m 0.6 0.1 Ignore targets closer than this
mmWave Max Distance 0-25 m 12 0.1 Ignore targets farther than this
mmWave Trigger Distance 0-25 m 6 0.1 Distance threshold for initial trigger
mmWave Sustain Sensitivity 0-9 7 1 Sensitivity after initial detection
mmWave Trigger Sensitivity 0-9 5 1 Sensitivity for initial detection
mmWave On Latency 0-2 s 0 0.25 Delay before reporting presence
mmWave Off Latency 1-600 s 15 5 Delay before clearing presence
Temperature Offset -10 to 10 °C 0 0.1 Calibration offset
Humidity Offset -20 to 20 % 0 1 Calibration offset
Illuminance Offset -100 to 100 lx 0 5 Calibration offset
mmWave Threshold Factor* 1-20 5 1 Detection threshold (Distance mode)

Configuration Selects

Entity Options Default Description
mmWave Mode* Presence Detection, Distance and Speed Presence Detection Operating mode
Distance/Speed Update Rate* 0.3s, 0.4s, 0.5s 0.5s How often distance values update

Switches

Entity Default Description
mmWave sensor* On Start/stop mmWave sensor
UART presence output* Off Enable UART presence data
UART target output* Off Enable UART target data
Micro-motion Detection* Off Detect very small movements

Buttons

Entity Description
Set Distance Apply distance settings to sensor
Set Sensitivity Apply sensitivity settings to sensor
ESP Reboot Restart the device
Factory Reset mmWave* Reset mmWave to factory defaults

Lights

Entity Description
mmWave LED Toggle mmWave sensor LED
ESP32 LED Toggle ESP32 status LED

Everything Presence Lite (EPL) - LD2450

Binary Sensors

Entity Description
Occupancy Overall room presence
Zone 1-4 Occupancy Presence in specific zone
Target 1-3 Active Whether each target slot is active
Assumed Present Assume present mode is active

Sensors

Entity Unit Description
Illuminance lx Ambient light level
Zone 1-4 Target Count - Targets in each zone
Occupancy Mask 1-2 Target Count - Targets in exclusion areas
Target 1-3 X mm Horizontal position
Target 1-3 Y mm Distance from sensor
Target 1-3 Distance mm Direct distance
Target 1-3 Angle ° Angle from center
Target 1-3 Speed mm/s Movement speed
Target 1-3 Resolution mm Detection resolution
Assumed Present Remaining s Countdown for assumed presence

Configuration Numbers

Entity Range Default Step Description
Occupancy Off Delay 0-600 s 15 1 Delay before clearing occupancy
Max Distance 0-600 cm 600 1 Maximum detection range
Installation Angle -45 to 45 ° 0 1 Virtual orientation adjustment
Illuminance Offset -100 to 100 lx 0 5 Calibration offset
Assume Present Timeout 0-600 s 15 1 Duration to assume presence
Exit Threshold Pct 0-100 % 10 1 Exit detection sensitivity
Zone 1-4 Begin/End X -6000 to 6000 mm 0 10 Zone horizontal bounds
Zone 1-4 Begin/End Y 0-6000 mm 0 10 Zone distance bounds
Zone 1-4 Off Delay 0-600 s 0 1 Per-zone off delay
Occupancy Mask 1-2 Begin/End X/Y varies 0 10 Exclusion zone bounds
Entry Zone 1-2 Begin/End X/Y varies 0 10 Entry zone bounds
Stale Target Timeout 0-600 s 30 1 Clear stuck targets after

Configuration Selects

Entity Options Default Description
Tracking Behaviour None, Targets Position, +Zone Count, +Targets Active, +Distance/Angle, +Speed/Resolution +Speed/Resolution Which sensors to report
Update Speed 0.1s, 0.2s, 0.3s, 0.5s, 1s 0.3s Reporting frequency
Extra Entities Update Every update, 2nd, 3rd, 5th, 10th Every update Update frequency for extras

Switches

Entity Default Description
Stale Target Reset Off Enable automatic target clearing
Inverse Mounting Off Flip for upside-down installation
Entry Exit Enabled Off Enable entry/exit zone detection
Polygon Zones Off Enable polygon zone mode
mmWave Bluetooth* Off Enable LD2450 Bluetooth

Buttons

Entity Description
ESP Reboot Restart the device
Factory Reset mmWave* Reset mmWave to factory defaults

Lights

Entity Description
ESP32 LED Toggle ESP32 status LED

Notes