Best Practices: Room-by-Room Setup Guide
Choose presence sensor settings for different rooms. Explore placement and tuning recommendations for hallways, bathrooms, bedrooms and living spaces.
Optimised settings and placement tips for common room types. These recommendations work for both EP1 and EPL sensors unless otherwise noted.
Bathroom
Bathrooms are ideal for presence sensors - automating lights based on occupancy works brilliantly here.
Recommended Placement
- Position: Corner of the room, aimed towards the toilet/shower area
- Height: 1.5-2m from floor
- Avoid: Mounting directly above the toilet (blind spot directly below)
Recommended Settings
| Setting | EP1 | EPL |
|---|---|---|
| Max Distance | Match room size (typically 3-4m) | Match room size |
| Sensitivity | Medium-high (6-7) | N/A |
| Off Delay/Latency | 60-120 seconds | 60-120 seconds |
Tips
- Higher off delay prevents lights turning off mid-shower
- Consider adding a humidity sensor trigger to keep the extractor fan running
- EPL zones can separate toilet area from shower for different automations
Bedroom
Sleep detection and gentle wake-up automations are popular bedroom uses.
Recommended Placement
- Position: Corner opposite the bed, angled towards the bed
- Height: 1.5-2m from floor
- Avoid: Directly above the bed (difficult to detect lying down)
Recommended Settings
| Setting | EP1 | EPL |
|---|---|---|
| Max Distance | Cover bed area only (3-5m) | Cover bed area only |
| Sensitivity | High (7-8) for sleep detection | N/A |
| Off Delay/Latency | 300+ seconds (5+ minutes) | 300+ seconds |
Tips
- Sleep detection: High sensitivity can detect breathing/micro-movements
- Partner-friendly: Long off delay prevents lights triggering if one person gets up briefly
- EPL advantage: Create a zone just for the bed area to detect "in bed" vs "in room"
Common Issues
- Ceiling fans can cause false positives - reduce max distance to exclude fan
- Pets on the bed will trigger detection
Office / Home Desk
Desk presence is perfect for automating monitors, lights, and heating.
Recommended Placement
- Position: Mounted on desk or shelf, aimed at the chair
- Height: Desk level works well
- Distance: 1-2m from the chair position
Recommended Settings
| Setting | EP1 | EPL |
|---|---|---|
| Max Distance | 2-3m (just covers desk area) | 2-3m |
| Sensitivity | High (7-8) for typing detection | N/A |
| Off Delay/Latency | 300-600 seconds | 300-600 seconds |
Tips
- High sensitivity detects typing and small movements
- Long off delay handles quick trips to make coffee
- EP1: "Distance & Speed Mode" shows exactly where detection is occurring
- EPL: Create a small zone around the desk chair
Automation Ideas
- Turn on desk lamp and monitor when occupied
- Start a "focus mode" after 5 minutes of presence
- Turn off when leaving (with appropriate delay)
Living Room
Larger spaces benefit from careful zone planning, especially with EPL.
Recommended Placement
- Position: Corner of room with view of main seating areas
- Height: 1.5-2m from floor
- Coverage: Aim to cover sofa/TV area primarily
Recommended Settings
| Setting | EP1 | EPL |
|---|---|---|
| Max Distance | Room size minus 1m (avoid detecting through walls) | Room size |
| Sensitivity | Medium (5-6) | N/A |
| Off Delay/Latency | 120-300 seconds | 120-300 seconds |
Tips
- Detecting through walls: If you get false positives from adjacent rooms, reduce max distance
- TV watching: People sitting still watching TV can be challenging - use higher sensitivity
- EPL zones: Create separate zones for sofa, dining area, and walkways
EPL Zone Strategy
- Sofa zone: Primary presence area
- Walkway zone: Triggers immediate lights but shorter timeout
- Exclusion mask: Block windows or areas causing false triggers
Hallway / Corridor
Fast response times are essential for hallways - you want lights on before you walk into darkness.
Recommended Placement
- Position: One end of the hallway, aimed down the length
- Height: 2m+ to avoid triggering on pets
- For L-shaped hallways: Consider two sensors or position at the corner
Recommended Settings
| Setting | EP1 | EPL |
|---|---|---|
| Max Distance | Full hallway length | Full hallway length |
| Sensitivity | Medium (5-6) | N/A |
| Off Delay/Latency | 30-60 seconds (short!) | 30-60 seconds |
| On Latency | 0 (instant) | N/A |
Tips
- Speed is key: Use minimal on latency for instant response
- Short off delay: Nobody lingers in hallways
- EPL entry/exit: Great for tracking direction of movement
Kitchen
Kitchens need to handle both active cooking (lots of movement) and passive presence (standing at the counter).
Recommended Placement
- Position: Away from the hob/stove (steam and heat can affect sensors)
- Height: 1.5-2m, aimed at main work areas
- Avoid: Direct line of sight to extractor fan or boiling pans
Recommended Settings
| Setting | EP1 | EPL |
|---|---|---|
| Max Distance | Room size | Room size |
| Sensitivity | Medium-high (6-7) | N/A |
| Off Delay/Latency | 180-300 seconds | 180-300 seconds |
Tips
- Longer off delay handles time spent at the sink or counter
- Avoid mounting near steam sources
- Consider the fridge - door opening can trigger PIR
Garage / Workshop
Larger spaces with vehicles present unique challenges.
Recommended Placement
- Position: High corner, angled down
- Height: 2m+
- Coverage: Focus on work areas, not parked vehicles
Recommended Settings
| Setting | EP1 | EPL |
|---|---|---|
| Max Distance | Depends on layout | Create zones for work areas |
| Sensitivity | Medium (5-6) | N/A |
| Off Delay/Latency | 300+ seconds | 300+ seconds |
Tips
- EPL zones: Essential here - exclude the car parking area to avoid false triggers
- Metal surfaces can reflect mmWave signals unexpectedly
- Large temperature swings may affect readings
Outdoor / Covered Areas
Warning
The EP1 and EPL are designed for indoor use. Outdoor use is not officially supported and may void warranty.
If you do use sensors in covered outdoor areas (patios, porches):
Considerations
- Must be fully protected from rain and direct sunlight
- Temperature extremes affect sensor performance
- Wind can cause movement that triggers detection
- Consider IP-rated enclosures
Settings Adjustments
- Lower sensitivity to reduce false positives from environmental movement
- Shorter max distance to avoid detecting passing traffic or pedestrians
- Test thoroughly in different weather conditions
General Best Practices
Power Supply Quality
A quality USB power supply makes a significant difference. Poor or noisy power can cause:
- WiFi connectivity issues
- Erratic mmWave readings
- False positives/negatives
Use a reputable brand power supply rated for at least 1A.
Mounting Surface
- Mount on a stable, solid surface
- Avoid surfaces that vibrate (near washing machines, etc.)
- The ball joint mount allows fine adjustment of angle
Multiple Sensors in One Room
- Both EP1 and EPL can work alongside each other
- Multiple EPLs in one room may interfere - use different channels if supported
- Consider using one for presence and one for specific zone detection
Testing Your Setup
- Set up the sensor with default settings first
- Observe behaviour for 24-48 hours
- Adjust one setting at a time
- Wait 10 seconds between changes (EP1)
- Use the diagnostic entities to understand what the sensor "sees"
Quick Reference Card
| Room Type | Max Distance | Off Delay | Key Tip |
|---|---|---|---|
| Bathroom | Room size | 60-120s | Higher delay for showers |
| Bedroom | Bed area only | 300s+ | High sensitivity for sleep |
| Office | 2-3m | 300-600s | Zone around chair (EPL) |
| Living Room | Room -1m | 120-300s | Reduce to avoid wall penetration |
| Hallway | Full length | 30-60s | Instant on, short off |
| Kitchen | Room size | 180-300s | Away from steam/heat |
| Garage | Zoned (EPL) | 300s+ | Exclude vehicle areas |