How to Tune Your Pro
Tune Everything Presence Pro presence detection for your room. Follow the guide to adjust sensor settings and reduce unwanted detections.
The Everything Presence Pro has two mmWave sensors with different characteristics. This guide helps you optimize both for your room.
Understanding the Two Sensors
| Sensor | Range | Best For | Key Settings |
|---|---|---|---|
| Static (SEN0609) | Up to 25m | Detecting still people | Range, Sensitivity |
| Tracking (LD2450) | Up to 6m | Location, zones, movement | Range, Zones |
Both sensors contribute to the main Occupancy entity, so tuning either can improve your results.
Quick Tuning Checklist
- Set Static Presence Max Range to match your room depth
- Set Tracking Detection Range to match your room depth
- Add exclusion zones for problem areas (windows, fans)
- Adjust timeouts for your use case
- Fine-tune sensitivity if needed
Tuning the Static Presence Sensor (SEN0609)
Range Settings
| Setting | What It Does | Recommendation |
|---|---|---|
| Min Range | Ignores detections closer than this | Usually 0m (no minimum) |
| Max Range | Ignores detections beyond this | Set to room depth or slightly less |
| Trigger Range | Initial detection threshold | Usually same as Max Range |
To apply range changes:
- Set your desired values
- Click Apply Static Range Settings button
Sensitivity Settings
| Setting | What It Does | Higher Value |
|---|---|---|
| Trigger Sensitivity | How easily detection starts | More sensitive, more false triggers |
| Sustain Sensitivity | How easily detection maintains | More sensitive, stays on longer |
Recommended starting values:
- Trigger Sensitivity: 5 (default)
- Sustain Sensitivity: 7 (default)
To apply sensitivity changes:
- Set your desired values
- Click Apply Static Sensitivity Settings button
Common Issues & Fixes
| Issue | Solution |
|---|---|
| Detects through walls | Reduce Max Range to stop before the wall |
| Misses still people | Increase Sustain Sensitivity (7-9) |
| False triggers when empty | Reduce sensitivities, check for moving objects |
| Slow to detect | Increase Trigger Sensitivity, reduce On Delay |
Tuning the Tracking Sensor (LD2450)
Detection Range
Set Tracking Detection Range to approximately your room depth in cm:
- Small room (3m): 300cm
- Medium room (4-5m): 400-500cm
- Maximum (6m): 600cm
Zone Configuration
For precise control, use the Zone Configurator to:
- Create detection zones for specific areas
- Add exclusion zones to ignore problem spots
- Visualize real-time tracking
Exclusion Zones
Use exclusion zones for:
- Windows (people walking by outside)
- Ceiling fans
- Curtains that move
- Areas detected through thin walls
Update Rate Settings
| Setting | Trade-off |
|---|---|
| Tracking Update Rate | Faster = more responsive, more CPU usage |
| Target Update Rate | Faster = more HA database writes |
| Target Tracking Detail | More detail = more entities updated |
For most users: Keep defaults. Only reduce if you have performance issues.
Timeout Settings
| Room Type | Occupancy Timeout | Motion Timeout |
|---|---|---|
| Hallway/passage | 15-30s | 10s |
| Bathroom | 60-120s | 15s |
| Kitchen | 30-60s | 10s |
| Living room | 120-300s | 15s |
| Office/desk | 300-600s | 15s |
| Bedroom | 300-600s | 15s |
Longer timeouts prevent lights turning off while you're still present but sitting still.
Combining Both Sensors
The Pro's Occupancy entity combines both mmWave sensors plus PIR:
Occupancy = PIR Motion OR Static Presence OR Tracking Presence
This means:
- PIR provides instant motion response
- Static sensor provides long-range stationary detection
- Tracking sensor provides zone awareness
You can also use individual sensors for specific automations:
- Use Motion (PIR) for instant-on lighting
- Use Static Presence for long-range detection
- Use Tracking Presence or Zone entities for location-specific triggers
Troubleshooting Detection Issues
Sensor detects when room is empty
- Check for moving objects (fans, pets, curtains)
- Reduce Max Range if detecting through walls
- Add exclusion zones for problem areas
- Lower sensitivity settings
Sensor misses people who are sitting still
- Increase Static Sustain Sensitivity (7-9)
- Ensure line of sight to the seating area
- Check Max Range includes the seating area
Detection is slow
- Increase Static Trigger Sensitivity
- Reduce Static On Delay to 0
- Ensure adequate Tracking Update Rate
Zones not working correctly
- Use Zone Configurator to visualize real-time tracking
- Verify zone coordinates cover the intended area
- Check exclusion zones aren't masking valid detections