The Everything Presence Pro exposes many entities in Home Assistant. This page explains each one and when to use it.
Presence & Occupancy Sensors
Binary Sensors
| Entity |
Description |
Use Case |
| Occupancy |
Combined presence from PIR + Static + Tracking sensors |
Main automation trigger (recommended) |
| mmWave Presence |
Combined presence from Static + Tracking sensors |
mmWave-only detection without PIR |
| Static Presence |
SEN0609 sensor only |
Long-range stationary detection (up to 25m) |
| Tracking Presence |
LD2450 sensor only |
Zone-based detection (up to 6m) |
| Motion |
PIR sensor only |
Fast initial motion detection |
Which Sensor Should I Use?
For most automations, use Occupancy. It combines all sensors for the best balance of:
- Fast response (from PIR)
- Stationary detection (from Static sensor)
- Location awareness (from Tracking sensor)
Tracking Sensors (LD2450)
These sensors provide real-time position data for up to 3 targets.
Target Position Sensors
| Entity |
Description |
| Target 1/2/3 X |
Horizontal position in mm (negative = left, positive = right) |
| Target 1/2/3 Y |
Distance from sensor in mm |
| Target 1/2/3 Distance |
Direct distance from sensor in mm |
| Target 1/2/3 Angle |
Angle from sensor center in degrees |
| Target 1/2/3 Speed |
Movement speed in m/s |
| Target 1/2/3 Resolution |
Detection resolution in mm |
| Target 1/2/3 Active |
Whether this target slot is currently tracking someone |
Zone Sensors
| Entity |
Description |
| Zone 1/2/3/4 Presence |
Whether someone is detected in this zone |
| Zone 1/2/3/4 Target Count |
Number of targets in this zone |
| Exclusion Zone 1/2 Target Count |
Targets in exclusion zones (for debugging) |
Info
Zone 2-4 entities are disabled by default to reduce database load. Enable them in Home Assistant if needed.
Static Presence Sensors (SEN0609)
| Entity |
Description |
| Static Presence |
Binary presence detection from SEN0609 |
Environmental Sensors
| Entity |
Description |
Notes |
| Temperature |
Room temperature |
May be affected by device heat - see FAQ |
| Humidity |
Relative humidity |
May be affected by device heat - see FAQ |
| Illuminance |
Light level in lux |
Accurate measurement |
| CO2 |
Air quality in ppm |
Only with CO2 module installed |
Controls
Timeouts
| Entity |
Range |
Description |
| Occupancy Timeout |
1-600s |
Delay before Occupancy turns off |
| Motion Timeout |
1-120s |
Delay before Motion (PIR) turns off |
| Static Presence Timeout |
1-600s |
Delay before Static Presence turns off |
| Tracking Presence Timeout |
0-600s |
Delay before Tracking Presence turns off |
| Zone 1/2/3/4 Timeout |
0-600s |
Per-zone off delay |
Static Sensor Settings (SEN0609)
| Entity |
Range |
Description |
| Static Presence Min Range |
0-25m |
Minimum detection distance |
| Static Presence Max Range |
0-25m |
Maximum detection distance |
| Static Presence Trigger Range |
0-25m |
Initial trigger distance |
| Static Presence On Delay |
0-2s |
Delay before presence triggers |
| Static Presence Trigger Sensitivity |
0-9 |
Sensitivity for initial detection |
| Static Presence Sustain Sensitivity |
0-9 |
Sensitivity for maintaining detection |
Tracking Sensor Settings (LD2450)
| Entity |
Range |
Description |
| Tracking Detection Range |
0-600cm |
Maximum tracking distance |
| Tracking Sensor Angle |
-45 to 45° |
Compensation for angled mounting |
| Tracking Update Rate |
Various |
How often position updates (affects CPU) |
| Target Update Rate |
Various |
How often target entities update |
| Target Tracking Detail |
None to Full |
Which target sensors to update |
Zone Configuration
| Entity |
Description |
| Zone 1/2/3/4 Start X/Y |
Zone corner coordinates in mm |
| Zone 1/2/3/4 End X/Y |
Zone opposite corner coordinates in mm |
| Exclusion Zone 1/2 Start/End X/Y |
Exclusion zone coordinates |
Tip
Use the Zone Configurator for visual zone setup instead of editing coordinates manually.
Relay & Alarm
| Entity |
Description |
| Relay Output |
Manual relay control (on/off) |
| Relay Trigger Mode |
Automatic trigger mode (Disabled/Motion/Presence/Both) |
| Relay Contact Type |
Normally Open (NO) or Normally Closed (NC) — default: NO |
LED Control
| Entity |
Description |
| LED |
Manual LED color/brightness control |
| LED Mode |
Automatic LED behavior (Manual/Presence/Environmental/Both) |
| LED Brightness |
Brightness multiplier for automatic modes |
Calibration
| Entity |
Description |
| Temperature Calibration |
Offset to adjust temperature reading |
| Humidity Calibration |
Offset to adjust humidity reading |
| Illuminance Calibration |
Offset to adjust light level reading |
| Entity |
Description |
| Restart Device |
Restart the Pro |
| Apply Update |
Apply firmware variant changes |
| Apply Static Range Settings |
Save range settings to SEN0609 |
| Apply Static Sensitivity Settings |
Save sensitivity settings to SEN0609 |
| Calibrate CO2 |
Force CO2 sensor calibration (CO2 module only) |
Switches
| Entity |
Description |
| Static Presence Sensor Enable |
Enable/disable the SEN0609 sensor |
| LD2450 Bluetooth |
Enable/disable Bluetooth on the LD2450 (for firmware updates) |
| Upside Down Mounting |
Flip coordinates for inverted mounting |
| Auto-Clear Stuck Targets |
Automatically reset stuck target detections |
Diagnostic Entities
| Entity |
Description |
| Device Info |
ESP32 device information |
| Reset Reason |
Last restart reason |
| Tracking Sensor Firmware |
LD2450 firmware version |
| Network Type |
Current network connection (WiFi/Ethernet) |
| CO2 Sensor |
Whether CO2 firmware is enabled |
| Bluetooth Proxy |
Whether Bluetooth proxy is enabled |